1. Keypad
ZERO
:
key
Sets the display to zero. (Zero range is within 2% of maximum
capacity. Initial zero point range is within 20% of maximum capacity)
TARE
:
key
Tares the weight on the scale platform.(Tare range is over 20d but
less than maximum capacity)
GROSS/NET
key: Toggles between gross and net weight.
Sleep/Wake
key
I/O key: Power on or off the scale
Note:
G.W.
=Gross weight
N.T.
Net weight = gross weight minus tare.
J
DI-800 can only use the OUTPUT DC 6V /2.5A adaptor. Battery is optional.
◎Please check the power source if there is sudden power failure.
2. Weighing Menu
M+:
Adds the indicated weight into Accumulation memory.
Note:
◎Only if the weight is over 20d, can it be accumulated.
◎ Remove the item and the display goes back to zero before the next
accumulation can register.
PRINT:
Outputs data.
print modes: manual print /Stable print
Note: Turn off the printer before connect to the scale.
MC:
clears previous accumulation data.
Return:
Returns to previous menu.
3. COUNT Menu
MR:
Adds the indicated weight and piece count value into Accumulation
memory.
UW Lookup:
Recalls unit weight from memory.
Note: If there is no weight value or unit weight value, the UW Lookup is not
available.
Store UW:
Stores Unit weight into memory.
JADEVER SCALE CO., LTD
U s e r ' s M a n u a l JD
:
Toggles between standby mode and working mode.
JDI SCALE
I
1

Advertisement

loading

Summary of Contents for Jadever JKD 250

  • Page 1 JADEVER SCALE CO., LTD U s e r ’ s M a n u a l JD 1. Keypad ZERO Sets the display to zero. (Zero range is within 2% of maximum capacity. Initial zero point range is within 20% of maximum capacity) TARE Tares the weight on the scale platform.(Tare range is over 20d but...
  • Page 2 JADEVER SCALE CO., LTD Clear Count: Clears counting results. Deletes accumulation records. Adds the displayed quantity /weight into the accumulating memory. SAMPLE: Inputs the indicated sample size to calculate average unit weight. Inputs the indicated unit weight value to calculate the amount of load.
  • Page 3 JADEVER SCALE CO., LTD ◎only 1-D bar code is supported. 4.3 System Set Press to initiate system setup 1) Auto-Off: Sets the period of inactivity before the scale automatically turns off. 2) Sound: The scale has been installed button sound and weighing speaker.
  • Page 4 Sets filter level. The higher setting and the better shockproof. 10) Commport: Choose the communication port 11) CommMode: Choose the communication mode to Jadever weighing software 5. STOCK Menu After connecting to network, you could use this function for stock control.
  • Page 5 JADEVER SCALE CO., LTD ◎The stock function is available only after stable indication appears and there should be a weight or quantity value. ◎Remove the item and the display goes back to zero before the next stock action can register.
  • Page 6 JADEVER SCALE CO., LTD labeling standard for GS1 used as product identification for container and pallet levels in the supply chain. • 128A (Code Set A) - ASCII characters 00 to 95 (0-9, A-Z and control codes), special characters, and FNC 1-4 •...

This manual is also suitable for:

Jkd 500Jdi