Cabinet Layout

Carefully check the location where the range is to be
installed. For best performance, the range should be placed
away from drafts that may be caused by doors, windows and
heating and air conditioning outlets.
To reduce the risk of personal injury and to reduce
accumulated smoke in the room, Dacor strongly recommends
installing a range hood. A range hood should project
horizontally a minimum of 5 inches beyond the face of the
cabinets.
All maximum and minimum dimensions and clearances
shown in the diagrams below must be maintained for safe
operation.
The range may be installed flush to the rear wall. Dacor
strongly recommends installing a non-combustible material
on the rear wall above the range and up to the vent hood or
installation of a backguard. It is not necessary to install non-
combustible materials behind the range below the countertop
height.
Any openings in the wall behind the appliance or in the floor
underneath it must be sealed.
CUTOUT DIMENSIONS
Range Model
F
42" (106.7 cm)*
ER36D
36" (91.4 cm)**
54" (137.2 cm)*
ER48D
48" (121.9 cm)**
* Recommended ** Minimum
Standard Cutout with
Range Hood
F
13" (33.0 cm)
4
max.
Non-combustible
surface along
back wall
recommended
30" (76.2 cm)
18" (45.7 cm)
1
min.
3, 4
min.
Note 2
36 1/2"
(92.7 cm)
max.
6
Planning the Installation
G
H
36 1/16"
33 1/2"
(91.6 cm)**
(84.8 cm)
48 1/16"
43 1/2"
(122.1 cm)**
(110.2 cm)
G
Suggested
location of
3
utilities
1
Vertical to combustible surface from range grate level; if
installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Vertical distance from range top panel level.
4
This specification does not apply for cabinets more
than a horizontal distance of 10" (25.4 cm) from the
edge of the range.
Gas and Electrical Service
The shaded area shown denotes the suggested location of
the gas inlet and the electrical junction box/receptacle. For
replacement purposes, the location of the existing utilities
may be utilized provided they do not interfere with the
sides or rear of the range. Check local building codes for
permissible gas valve locations.
An external manual shut-off valve must be installed between
the gas inlet and the range, for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed.
Access to the remote circuit breaker panel/fuse box, when the
range is in place.
The gas supply piping and shut-off valve, and the electrical
junction box/receptacle must be located so they do not
interfere with the range when it is installed.
The junction box and gas shut off valve must be located
so that the range can be pulled out for service while the
appliance remains connected.
Minumum Countertop Height:
30 1/4" (76.8 cm)
Maximum Countertop Height:
36 1/2" (92.7 cm)
non-combustible
rear wall recommended
Cutout with Optional Downdraft Vent
10" (25.4 cm) min.
to combustible side
walls above the range
(both sides)
APPROVED DOWNDRAFT MODEL NUMBERS
Range Model
ER36D
ER48D
IMPORTANT: See the downdraft installation instructions
for the duct and electrical installation requirements. Use
only the downdraft vent models specified above.
Cutout tolerances: +1/16" (+1.6 mm), -0
unless otherwise stated
Backsplash
2 13/16"
(7.1 cm)
3/8" (1.0 cm)
Min. flat countertop
overhang
H
10" (25.4 cm) min.
to combustible side
Note 2
walls above the range
(both sides)
G
(Top View)
Downdraft Vent Model
ERV36-ER
ERV48-ER

Advertisement

Table of Contents
loading

This manual is also suitable for:

Er48dEr36d-cEr48d-c

Table of Contents