_PerfectCharge_IU152A-IU802A.book Seite 48 Dienstag, 15. September 2009 5:19 17

Using the IU0U automatic charger

➤ Insert the plug of the remote control in the "RC" socket (fig. d 3, page 10)
of IU0U automatic charger.
10
Using the IU0U automatic charger
You can use the IU0U automatic charger to trickle charge empty batteries or
supply batteries.
Note
I
The chargers IU152A, IU252A and IU154A have a charger output
for the starter battery with an output voltage in the range between
13.2 V (26.4 V) and 13.8 V (27.6 V). The charger output for the
starter battery recharges the starter battery with a current of up to
1 A or maintains a high charge level.
➤ Switch on the device with the main switch (fig. 2 1, page 3).
10.1
Setting the IU0U automatic charger (fig. 8, page 7)
Charging voltage and time limit
Note
I
Ask your battery retailer for details on the charging voltage and time
limit required for your batteries.
Caution
a
Make sure that the device is never used if DIP switches 1 and 2 or
DIP switches 3 and 4 are both at the "ON" position. Only the switch
positions described in the following tables ensure the correct oper-
ation of the IU0U automatic charger.
➤ Turn the main switch to "0".
➤ Unscrew the four fastening screws (2) from the rear panel using the hex-
agon socket wrench provided.
➤ Remove the rear panel (1).
➤ Use the DIP switches (5) to set the required charging voltage and the du-
ration of the main charging phase (U0 phase, also see chapter "Charging
characteristics" on page 51):
48