Conditioning The Battery - Waeco IU152A Installation And Operating Manual

Perfectcharge iu0u automatic charger
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 36
_PerfectCharge_IU152A-IU802A.book Seite 50 Dienstag, 15. September 2009 5:19 17
Using the IU0U automatic charger
10.3

Conditioning the battery

To prevent any sulphation of the battery during prolonged non-use (during
the winter), it must be charged beforehand.
➤ If applicable, disconnect the starter battery from the charger.
➤ Connect the battery to be charged.
➤ Set the DIP switch (fig. 8 5, page 7):
– Switch 4: ON
– Wet batteries: Switch 3: ON
Gel/fleece batteries: Switch 3: OFF
➤ Set the main switch on the IU0U-automatic charger (fig. 2 1, page 3) to
"I".
✓ The battery will be charged for 8 hours (switch 3: ON) or for 16 hours
(switch 3: OFF) at the charging voltage which has been set.
When this time has passed, the IU0U-automatic charger automatically
switches to the retentionphase.
Note
I
A slight overcharging could occur, in wet batteries indicated by es-
caping gases and in gel/fleece batteries by slight warmth.
➤ After conditioning, turn switch 4 on the DIP switch (fig. 8 5, page 7)
to "OFF".
You will thereby prevent any repetition of the conditioning caused by
switching the charger off and on again, which can damage the battery.
50
PerfectCharge

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iu254aIu452aIu252aIu404aIu802aIu154a

Table of Contents