FEATURES:

1.
Standard mode.
2.
Easy motor direction change. (via jumper)
3.
Auto close facility.
1.

Standard Mode. (No function selected).

When the gate is activated it will open and can be stopped in mid cycle by pressing the
transmitter or manual push button. Pressing the transmitter or push button can reverse the
gate. In standard mode the gate will remain on its open limit until it is triggered to close.
If main power fails, the motor will still operate until battery reaches 9.5Volt
manual by overriding the motor by the override lever. When the main power comes on
again, lock in the override lever and the motor will function as normal.
2.

Easy motor direction change.

By selecting the jumper, the motor direction and the limit wires are changed
automatically. (Please note: the gate must close on first trigger after power up).
3.
Auto close. (20 seconds, fixed)
When Auto close is selected via the jumper on the PCB and the Gate opens to the open
limit, the gate will wait the factory default time before automatically closing. If the gate is
triggered while the gate is in its closing cycle it will stop and reopen.
If the transmitter or manual push button is pressed while the gate is in its opening cycle, the
gate will stop and close after the factory default auto close time (from any position, not
only from the open limit).
4.
Pedestrian function
A default auto close time (8 Seconds) and opening distance (Approximately 1 meter) has
been preprogrammed and cannot be changed.
List of LED indications.
- LED ON when open limit is activated. (gate open).
- LED OFF when close limit is activated. (gate closed).
- LED flashing SLOW (1 sec. on/1 sec. off) (gate is in motion).
- LED flashes 2 long/3 short continuously (gate is stopped midway).
- LED flashes fast (250ms on/250ms off) continuously. (gate in overload).
- LED flashes 3 fast flashes every 1.5 seconds. (Battery low, <11VDC).
NB – When connecting intercoms to the control card (IT and CMN), please ensure that your intercom
trigger output is potential free (ZERO voltage). If not, a gate relay module must be fitted.

ELECTRONICS

(Infra red beams must be fitted if auto close is
(Infra-red beams must be fitted if auto close is selected).
6
activated).