Operating Heater; Manual Lighting - Comfort Glow CF26PR Owner's Operation And Installation Manual

Vent-free propane/lp gas bay front fireplace
Table of Contents

Advertisement

OPERATING
HEATER
Continued
Note: If pilot does not stay lit, con-
tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure.
8. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps
4 through 8.
9. Slightly push in and turn control
knob counterclockwise
ON position.
10. Wait one minute and switch selector
switch to the ON position to light
burner. Note: AUTO is only func-
tional when using GWMT1 or
GWMS2 optional accessories.
11. Set flame adjustment knob to any
level between HI and LO.
CAUTION: Do not try to adjust
heating levels by using the
manual shutoff valve.
WARNING: Make sure the
selector switch is in the OFF po-
sition when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.
Pilot Burner
Figure 34 - Pilot
105442
Shutting Off Heater
1.
Turn control knob clockwise
to the OFF position.
2a. Set selector switch in the OFF position
2b. If Using Optional Hand-Held Re-
mote: Set selector switch in the OFF
position to keep from draining battery.
Shutting Off Burner Only (pilot
stays lit)
You may shut off the burner and keep the
pilot lit by doing one of the following:
1.
Turn control knob clockwise
to the PILOT position.
2.
Use remote control manual OFF button.
3.
Set selector switch in the OFF position.
to the
1.
Follow steps 1 through 6 under Light-
ing Instructions, page 16.
2.
Depress control knob and light pilot
with match.
3.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 9 through 11, column 1.
OPTIONAL REMOTE
Note: All remote control accessories must
be purchased separately (see Accessories,
page 28). Follow instructions included
with the remote control.
Thermostat Control Operation
(Optional CGHRCT Series Only) The
thermostat control setting on the remote
control unit can be set to any comfort
level between HI and LO. The burner will
Ignitor
Electrode
turn on and off automatically to maintain
the comfort level you select. The ideal
comfort setting will vary by household
depending upon the amount of space to
be heated, the output of the central heat-
ing system, etc.
OWNER'S MANUAL
TO TURN OFF GAS
TO APPLIANCE

MANUAL LIGHTING

PROCEDURE
OPERATION
17
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See Lighting
Instructions on page 16 and 17.
1.
After lighting, let pilot flame burn for
about one minute. Turn control knob
to ON position. Adjust flame adjust-
ment knob anywhere between HI
and LO. Slide the selector switch to
the REMOTE position. NOTE: The
burner may light if hand-held remote
ON button was on when selector
switch was last turned off. You can
now turn the burner on and off with
the hand-held remote control unit.
IMPORTANT: Do not leave the selector
switch in the REMOTE position when the
pilot is not lit. This will drain the battery.
IMPORTANT: Be sure to press the ON/
OFF buttons on the hand held remote
control unit for up to 3 seconds to assure
proper operation.
CGHRC Operation:
2a. Press the ON/OFF button to turn the
burner on and off. When turning
burner off, the pilot will remain lit.
CGHRCT Operation
2b. Select the MAN (manual) or AUTO
button on the hand-held remote con-
trol unit (see Figure 36, page 18)
• In manual mode, turn burner on
or off by pressing the ON or OFF
buttons on the hand-held remote
control unit.
• In auto mode, the room tempera-
ture is controlled by the thermo-
stat in the hand-held remote con-
trol unit. To increase the room tem-
perature, press the top arrow of the
TEMP button. To lower room the
temperature, press the bottom ar-
row of the TEMP button. At higher
settings the heater will run more.
IMPORTANT: This remote control has
been specially engineered to take an air
temperature sample every 5.5 minutes in
the auto mode. It will not respond imme-
diately to the temperature setting being
turned up or down.
Continued