Connecting Fireplace To Gas Supply - Comfort Glow CF26PR Owner's Operation And Installation Manual

Vent-free propane/lp gas bay front fireplace
Table of Contents

Advertisement

INSTALLATION
Continued
CONNECTING FIREPLACE
TO GAS SUPPLY
Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not
provided)
1.
Route flexible gas line (provided by in-
staller) from manual shutoff valve into
fireplace through side or rear access
holes in outer casing (see Figure 22).
NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
from the fireplace (see Figure 23).
The flexible gas supply line con-
nection to the manual shutoff
valve should be accessible.
2.
Apply pipe joint sealant lightly to male
threads of gas connector attached to
flexible gas line (see Figure 23). Con-
nect flexible gas line to flexible gas line
attached to gas valve of fireplace (see
Figure 23).
3. Check all gas connections for leaks. See
Checking Gas Connections, page 14.
4.
Feed flexible gas line into fireplace base
area. Make sure the entire flexible gas
line is in fireplace mantel base area.
CAUTION: Avoid damage to
regulator. Hold gas regulator with
wrench when connecting it to gas
piping and/or fittings.
105442
Figure 22 - Routing Flexible Gas Line
Manual Shutoff Valve
To Gas
Flexible Gas Line from
Supply
Manual Shutoff Valve
Provided by Installer
Figure 23 - Attaching Flexible Gas Lines Together
13
OWNER'S MANUAL
Outer
Casing
Manual
Shut Off
Valve
Gas Connector
To Fireplace
Gas Valve
Flexible Gas Line from
Fireplace Gas Valve
Provided with Fireplace
Continued

Advertisement

Table of Contents
loading

Table of Contents