INSTALLATION
Continued
INSTALLING BLOWER
ASSEMBLY - GA3450T
For Built-In Installation
WARNING: A licensed electri-
cian must connect the wiring har-
ness to electrical supply follow-
ing all local codes. Electrician
must provide a clamp on the box
cover to secure the wiring. Wir-
ing should be routed through the
bushing in the hole on the outer
casing of heater.
1. Install a snap bushing found in hard-
ware kit into one of the holes found on
rear of blower control shield. The other
hole is for a strain relief clamp (not sup-
plied) to secure incoming electrical
supply.
2. Follow steps 2 through 6 in Installing
Blower Assembly, page 10. Also re-
move black wire from middle/OFF
switch terminal.
3.
Remove black plastic strain relief and
power cord from switch plate (see Fig-
ure 18). The power cord supplied will
not be used in built-in installations. Pop
in the plastic snap bushing found in hard-
ware kit into the hole left by supply cord/
strain relief.
4. A licensed electrician must follow the
wiring diagram in Figure 19 to connect
incoming electrical supply to fan kit
wiring harness.
5. Test to make sure the blower is work-
ing properly.
6.
Reinstall hood assembly (see page 9)
and close lower louver door.
7. Place log set back on the unit.
105442
Screw
Switch
Red
Blue
Switch
Plate
Blower
Control
Shield
Clamp Connector
(not included)
Figure 18 - Installing Blower Bracket Assembly
Fan Switch
(Auto/Off/On)
1
2
Off
3
On
110/115
V.A.C.
Black
Red
Green
White
Figure 19 - Wiring Diagram For Fan Accessory
Built-In Installation
11
OWNER'S MANUAL
Blower Bracket
Assembly
Wire
Strain
Harness
Relief
Power
Cord
Outlet
Receptacle
Shield
Cover
Wire
Harness
Auto
Thermostat
Blue
Switch
(N.O.)
Blue
Red
White
Green
Blower
Motor
Continued