Comfort Glow CGFB32C Owner's Operation And Installation Manual
Comfort Glow CGFB32C Owner's Operation And Installation Manual

Comfort Glow CGFB32C Owner's Operation And Installation Manual

Unvented (vent-free) universal firebox

Advertisement

Quick Links

UNVENTED (VENT-FREE)
UNIVERSAL FIREBOX
OWNER'S OPERATION AND INSTALLATION MANUAL
CGFB32C
Circulating
Louvered
Model
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property
damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas supplier.
This firebox may be installed in an aftermarket* manufactured (mobile) home, where not prohibited
by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer (i.e. Installation of this product is
permitted after the manufactured (mobile) home is sited).
Save this manual for future reference.
®
Shown with optional
cabinet mantel and
hearth base.
WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or addi-
tional information consult a quali-
fied installer, service agency, or
the gas supplier.
WARNING: For use only with
decorative type unvented room
heaters. Do not build a wood fire.
This firebox has been tested and
approved by I.A.S. under their
REQ. 2-97 for use with any ANS
Z21.11.2 approved gas logs.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CGFB32C and is the answer not in the manual?

Questions and answers

Summary of Contents for Comfort Glow CGFB32C

  • Page 1 UNVENTED (VENT-FREE) UNIVERSAL FIREBOX OWNER’S OPERATION AND INSTALLATION MANUAL CGFB32C Circulating ® Louvered Model Shown with optional cabinet mantel and hearth base. WARNING: Improper installa- WARNING: If the information in this manual is not followed tion, adjustment, alteration, ser- exactly, a fire or explosion may result causing property vice, or maintenance can cause damage, personal injury, or loss of life.
  • Page 2: Safety Information

    UNVENTED (VENT-FREE) FIREBOX SAFETY 5. You must operate this fireplace with the LOCAL CODES provided fireplace screen (closed), INFORMATION hood, and brick liner in place. Make Install and use fireplace with care. Follow all sure these parts are in place before run- local codes.
  • Page 3: Product Features

    When used without the blower the firebox requires no electricity " making it ideal for emergency backup heat. BLOWER ACCESSORY The CGFB32C firebox will accept the Built-in " GA3750 accessory. The variable blower Nailing "...
  • Page 4: Locating Firebox

    UNVENTED (VENT-FREE) FIREBOX LOCATING PROVIDING ADEQUATE Confined and Unconfined Space VENTILATION FIREBOX The National Fuel Gas Code (ANS Z2123.1, 1992 Section 5.3) defines a confined space The following are excerpts from National as a space whose volume is less than 50 Fuel Gas Code.
  • Page 5 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install firebox plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
  • Page 6 UNVENTED (VENT-FREE) FIREBOX AIR FOR COMBUSTION AND 12" VENTILATION Continued Ventilation Ventilation Grills Grills VENTILATION AIR Into Adjoining Room, Into Adjoining Option 2 Room, Ventilation Air From Inside Remove Option 1 Door into Building Adjoining This fresh air would come from an adjoining Room, unconfined space.
  • Page 7: Installation

    OWNER’S MANUAL Note: Your Comfort Glow firebox is de- Mantel Clearances for INSTALLATION signed to be used in zero clearance installa- Conventional Installation tions. Wall or framing material can be placed NOTICE: This firebox in combi- directly against any exterior surface on the...
  • Page 8 UNVENTED (VENT-FREE) FIREBOX Built-In Installation of Blower INSTALLING LOG HEATER IN INSTALLATION Accessory FIREBOX Continued 1. Install blower assembly per instruction CAUTION: Do not pick up log sheet included. INSTALLING BLOWER base assembly by burners. This 2. Before replacing bottom of firebox, ACCESSORY could damage burners.
  • Page 9 OWNER’S MANUAL INSTALLATION Assemble cabinet mantel, hearth base, Attach flexible gas line to log set. See and perimeter trim (Included with man- Connecting to Gas Supply in your log Continued tel). Assembly instructions are included set owner’s manual. with each accessory. 10.
  • Page 10 Figure 15 - Inserting Firebox Into Cabinet " owner’s manual. Mantel If using optional GA7090 brass trim kit, BUILT-IN FIREBOX 33" (CGFB32C) install the trim after final finishing and/ " (CGFB32NC) INSTALLATION or painting of wall. See instructions in- cluded with brass trim accessory for at- Built-in installation of this firebox involves taching brass trim.
  • Page 11: Technical Service

    OWNER’S MANUAL TECHNICAL ACCESSORIES SERVICE Purchase these fireplace accessories from your local dealer. If they can not supply You may have further questions about in- these accessories, call DESA International’s stallation, operation, or troubleshooting. If Sales Department at 1-800-432-2382 for so, contact DESA International’s Technical information.
  • Page 12: Illustrated Parts Breakdown

    UNVENTED (VENT-FREE) FIREBOX ILLUSTRATED PARTS BREAKDOWN CGFB32C 103573...
  • Page 13: Parts Centrals

    OWNER’S MANUAL PARTS LIST This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual. FIREBOX CGFB32C PART NUMBER DESCRIPTION QTY. CGFB32C 101872-03 Firebox Top 101889-01...
  • Page 14: Warranty Information

    We make no other warranty, expressed or implied. LIMITED WARRANTY COMFORT GLOW VENT-FREE RESIDENTIAL GAS HEATERS DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.

Table of Contents