IFM Electronic O3D301 Operating Instructions Manual page 53

3d camera
Table of Contents

Advertisement

Parameters only in "under5m_low"-type of application imager config
Parameter name
ExposureTime
ExposureTimeRatio
Channel
Default values of the "under5m_low" mode parameters
Parameter name
ExposureTime
Channel
Minimum and maximum values of the "under5m_low" mode parameters
Parameter name
ExposureTime
Channel
Parameters only in "under5m_moderate"-type of application imager config
Parameter name
ExposureTime
Channel
Data type
Description
Int
Time for the exposure
*has limits
The 2nd exposure time will be calculated based on the
first one.
Int
Ratio of long exposure time to short exposure time.
*has limits
Int
Allowed values:
*has limits
0: non-group use (like channel1 but additional GUI
option)
1: channel1
2: channel2
3: channel3
Data type
Default value
Int
1000
Int
0
Minimum value
0
0
Data type
Description
Int
Time for the long exposure
*has limits
The 2nd exposure time will be calculated based on the first
one.
Int
Allowed values:
*has limits
0: non-group use (like channel1)
1: channel1
2: channel2
3: channel3
3D camera
Maximum value
10000
3
53