Parameter name
SessionTimeout
ServiceReportFailedBuffer
ServiceReportPassedBuffer Int
ExtrinsicCalibTransX
ExtrinsicCalibTransY
ExtrinsicCalibTransZ
ExtrinsicCalibRotX
ExtrinsicCalibRotY
ExtrinsicCalibRotZ
IPAddressConfig
PasswordActivated
OperatingMode
DeviceType
ArticleNumber
ArticleStatus
UpTime
ImageTimestampReference Int
TemperatureFront1
Data type
Description
Int
Number of seconds which a session stays before a call
to "heartbeat" method is needed
*has limits
Int
Number of buffers reserved for failed results
*has limits
Number of buffers reserved for passed results
*has limits
Double
Extrinsic calibration, transition in X direction
Unit: millimetres
Double
Extrinsic calibration, transition in Y direction
Unit: millimetres
Double
Extrinsic calibration, transition in Z direction
Unit: millimetres
Double
Extrinsic calibration, rotation around X axis
Unit: degrees
Double
Extrinsic calibration, rotation around Y axis
Unit: degrees
Double
Extrinsic calibration, rotation around Z axis
Unit: degrees
Int
readonly: The GUI requires to know if the device is on
a discovery IP address for multiple-use cases. This
information was extended to reflect all kinds of IP-
address situations.
Allowed values:
0: Static (IP address explicitly defined inside the
device)
1: DHCP (using a DHCP server in the network)
2: LinkLocal (configured to DHCP, but no server which
provided an address)
3: Discovery (changed by IP4Discovery mechanism)
Bool
readonly: Is true if the password protection is enabled
Int
readonly: Mode of device (RUN, EDIT)
see "setOperatingMode" (the setter is outside the edit
mode but inside session)
String
readonly: Delivers a type description, unique by
imager, evaluation logic and device interface.
String
readonly: Official catalogue number
String
readonly: Official two-letter status code
Double
readonly: Hours since last reboot
readonly: This returns the current timestamp as a
reference for the timestamps in the received images.
Unit:
microseconds
Double
readonly: Temperature measured in the device.
Unit: celsius
Measured by first sensor on imager board.
3D camera
UK