IFM Electronic O3D301 Operating Instructions Manual page 41

3d camera
Table of Contents

Advertisement

requestSession
Method name
Description
Input parameters
Output parameters
reboot
Method name
Description
Input parameters
Output parameters
systemCommand
Method name
Description
Input parameters
Output parameters
requestSession
Requests a session object for access to the configuration and for
changing the device operating mode.
This blocks parallel editing and allows protection of editing with a
password.
The ID could optionally be defined by the external system but it must
be the defined format (32char "hex").
If it is called with only one parameter, the device will generate a
session ID.
The session will start with a default timeout ("SessionTimeout"
device parameter), the timeout can be extended by calling
"heartbeat".
The device will stay in RUN mode.
If password is disabled on the device, the value given as password
parameter is ignored.
1. Password: string
2. Session ID: string (optional)
Session ID: string
reboot
Reboot system, parameter defines which mode/system will be
booted
Type of system that should be booted after shutdown: int
0: Productive mode
1: Recovery mode
Output: string
systemCommand
Performs a generic command on the device.
1. Command: string
2. Parameter: string
Output: string