Venting Requirements - Kenmore 110.80754 Use And Care Manual

24" (61 cm) wide laundry center
Table of Contents

Advertisement

Available languages

Available languages

2=
4-wire connection:
Direct Wire
3=
Remove neutral ground wire from internal ground conductor
screw. Connect neutral ground wire and the neutral wire
(white or center wire) of power supply cord under center,
terminal block screw. Tighten screw.
A
/
ED
L
©
C
B
A. Center terminal block screw
B. Neutral ground wire
C. Internal ground conductor
screw - Dotted line shows
position of NEUTRAL ground wire before being
moved to center terminal block screw.
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL fisted strain relief
Move the green painted screw from the internal to the
external ground conductor location. Connect ground wire
(green or bare) of power supply cord to external ground
conductor screw. Tighten screw.
B
/
A .......
,........ C
A. Neutral wire (white or center wire)
B. Center terminal block screw
C. Neutral ground wire
D. External ground conductor screw
E. Ground wire (green or bare) of power supply cord
E Internal ground conductor
location
G. 3/4" (19 mm) UL listed, strain relief
4. Connect the other wires to outer terminal block screws.
Tighten screws.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection.
Now go to
"Venting Requirements."
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so
Laundry Center can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable, leaving
bare ground wire at 5" (127 mm). Cut 11/2"(38 mm) from
3 remaining wires. Strip insulation back 1" (25 mm). Shape ends
of wires into a hook shape.
_,,
(127
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example
below.
1=
2.
Remove center, terminal block screw.
Remove neutral ground wire from internal ground conductor
screw. Connect neutral ground wire and place the hooked
end (hook facing right) of the neutral wire (white or center
wire) of direct wire cable under the center screw of the
terminal block. Squeeze hooked ends together. Tighten
screw.
A
UoL
E D
C
A. Center terminal block screw
B. Neutral ground wire
C. Internal ground conductor
screw - Dotted line shows
position of NEUTRAL ground wire before being
moved to center terminal block screw.
D. Neutral wire (white or center wire)
E. 3/4" (19 mm) UL listed strain relief
11