Venting Requirements - Kenmore 8075 - 24 in. Laundry Center Use And Care Manual

24" (61 cm) wide laundry center washer- electric dryer
Table of Contents

Advertisement

Available languages

Available languages

1=
2.
Remove center, silver-colored
terminal block screw.
Remove neutral ground wire from internal ground conductor
screw. Connect neutral ground wire and the neutral wire
(white or center wire) of power supply cord under center,
silver-colored
terminal block screw. Tighten screw.
.....
B
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so
laundry center can be moved if needed.
Strip 5" (12.7 cm) of outer covering from end of cable, leaving
bare ground wire at 5" (12.7 cm). Cut 11/2 '' (3.8 cm) from
3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends
of wires into a hook shape.
A. Center silver-colored
terminal block screw
B. Neutral ground wire
C. Internal ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being
moved to center silver-colored
terminal block screw
D. Neutral wire (white or center wire)
E. 3/4" (1.9 cm) UL listed strain relief
Move the green painted screw from the internal to the
external ground conductor
location. Connect ground wire
(green or bare) of power supply cord to external ground
conductor
screw. Tighten screw.
B
G
F
E
D
A. Neutral wire (white or center wire)
B. Center silver-colored
terminal block screw
C. Neutral ground wire
D. External ground conductor
screw
E. Ground wire (green or bare) of power supply cord
F Internal ground conductor
location
G. 3/4"(1.9 cm) UL listed, strain relief
4. Connect the other wires to outer terminal block screws.
Tighten screws.
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection.
Now go to
"Venting Requirements."
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example
below.
1=
2.
Remove center, silver-colored
terminal block screw.
Remove neutral ground wire from internal ground conductor
screw. Connect neutral ground wire and place the hooked
end (hook facing right) of the neutral wire (white or center
wire) of direct wire cable under the center screw of the
terminal block. Squeeze hooked ends together. Tighten
screw.
.........
B
Io Ito
ED
C
A. Center silver-colored
terminal block screw
B. Neutral ground wire
C. Internal ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being
moved to center silver-colored
terminal block screw
D. Neutral wire (white or center wire)
E. 3/4, (1.9 cm) UL listed strain relief
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

110.80714110.88752

Table of Contents