Kenmore 110.80754 Use And Care Manual page 13

24" (61 cm) wide laundry center
Table of Contents

Advertisement

Available languages

Available languages

3-wire connection: Direct Wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so
Laundry Center can be moved if needed.
Strip 31/2"(89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw.
1=
2.
Loosen or remove center, terminal block screw.
Place the hooked end of the neutral wire (white or center wire)
of direct wire cable under the center screw of terminal block
(hook facing right). Squeeze hooked end together. Tighten
screw.
B
C
IL_
E
D
A. Neutral wire (white or center wire)
B. Center terminal block screw
C. Neutral ground wire
D. Internal ground conductor
screw
E. 3/4" (19 mm) UL listed, strain relief
3. Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection.
Now go to
"Venting Requirements."
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do
not permit connecting cabinet-ground
conductor to neutral wire.
1. Remove center, terminal block screw.
2. Remove neutral ground wire from internal ground conductor
screw. Connect neutral ground wire and the neutral wire
(white or center wire) of power supply cord/cable
under
center, terminal block screw. Tighten screw.
A ............ I o
°
"
E
C
A. Neutral wire (white or center wire)
B. Neutral ground wire
C. External ground conductor
screw
D. Grounding path determined
by a qualified electrician
E. Internal ground conductor
location
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Move the green painted screw from the internal to the
external ground conductor
location. Connect a separate
copper ground wire from the external ground conductor
screw to an adequate ground.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
13

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

110.88752

Table of Contents