Kenmore 110.80754 Use And Care Manual page 6

24" (61 cm) wide laundry center
Table of Contents

Advertisement

Available languages

Available languages

Alevel floor w ithamaximum s lope of1"(25 mm) u nder e ntire
Laundry Center. Clothes m ay nottumble properly and
automatic sensor cycles m ay notoperate c orrectly ifLaundry
Center isnotlevel. I nstalling oncarpet isnotrecommended.
Awater h eater settodeliver 120°F ( 49°C) water t othe
washer.
Hotandcold water f aucets l ocated w ithin 4 ft (1.2 m)ofthe
hotandcold water f illvalves, andwater p ressure of5-100 psi
(34.5-689.6 kPa).
The Laundry Center must n otbeinstalled orstored inanarea
where i twillbeexposed towater a nd/or w eather.
Donotoperate y ourwasher intemperatures
atorbelow
32°F (0°C). Some w ater c anremain i nthewasher andcan
cause damage inlowtemperatures.
See "Vacation, Storage,
andMoving C are" f orwinterizing information.
Donotoperate y ourdryer a ttemperatures
below 45°F (7°C). At
lower t emperatures,
thedryer m ight n otshut o ffattheendofan
automatic cycle. This canresult inlonger drying times.
Check c ode requirements.
Some codes limit, o rdonotpermit,
installation oftheLaundry Center ingarages, closets, mobile
homes, orsleeping quarters. Contact yourlocal b uilding
inspector.
Installation
Clearances
The location must be large enough to allow the dryer door to
open fully.
Laundry Center Dimensions
(1822 mini
*271/4"
(692 mm) ,,_.
15 3/8"
(390 ram)
321/8"
(816 ram)
"_- --{606 mm)
* Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum
spacing for recessed
area or closet
installation
The following spacing dimensions are recommended
for
this dryer. This Laundry Center has been tested for spacing
of 0" (0 mm) clearance on the sides, rear and top. Recommended
spacing should be considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing on all sides of the Laundry Center is
recommended
to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
o oo
o_O
m
1"--_(1_-23'/,"-N1÷_"
(25turn)
(606 rnm)
(26ram)
A
-H 1"*1_27,/,"+1
(26ram) (692 m m)
B
(25turn)
46in,2
(310 crn 2)
24in. 2 -
(155 cm2)
_e. 6"**
(127 mm)
,A
(76rnrn)
o
i___' (76mm}
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
**Rear clearance may be 0" (0 mm) when house exhaust system
is lined up directly with dryer exhaust.
Mobile Home - Additional
Installation
Requirements
This Laundry Center is suitable for mobile home installations.
The installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile home installations require:
Metal exhaust system hardware, which is available for
purchase from your local Sears store or Sears Service Center.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.