Figure 5.15 Pio Data-Out Command Protocol - Fujitsu MHV2200BT Product Manual

Table of Contents

Advertisement

Interface
An outline of this protocol is as follows:
1) The device receives a PIO data-out command with the RegHD FIS.
2) If an error remaining in the device prevents command execution, the device
sends the RegDH FIS with 1 set in the I bit.
3) When the device is ready to receive data, it sets 0 in the BSY bit and 1 in the
DRQ bit of the Status field of the PIO Setup FIS. At this time, the device sets
0 in the I bit of the Status field of the PIO Setup FIS for a data transfer to the
first sector, while it sets 1 in the I bit for a data transfer to any sector other
than the first sector. Then, it sends this FIS to the host. In the E_Status field,
the device sets 1 in the BSY bit and 0 in the DRQ bit.
4) The device receives the DATA FIS from the host.
5) When all data has been transferred, the device sends the RegDH FIS (with 1
set in the I bit) to complete execution of the command. If the device has an
error, it reports the error. If any data remains to be received by the device,
this protocol is repeated starting from step 3). (The maximum data size is 8
KB.)

Figure 5.15 PIO data-out command protocol

5-172
RegHD
PIO Setup
Host
DATA
RegDH
Device