Digital Pll Circuit - Fujitsu MHV2200BT Product Manual

Table of Contents

Advertisement

(3) FIR circuit
This circuit is 10-tap sampled analog transversal filter circuit that equalizes the
head read signal to the Modified Extended Partial Response (MEEPR) waveform.
(4) A/D converter circuit
This circuit changes Sampled Read Data Pulse from the FIR circuit into Digital
Read Data.
(5) Viterbi detection circuit
The sample hold waveform output from the flash digitizer circuit is sent to the
Viterbi detection circuit. The Viterbi detection circuit demodulates data
according to the survivor path sequence.

4.6.4 Digital PLL circuit

The drive uses constant density recording to increase total capacity. This is
different from the conventional method of recording data with a fixed data
transfer rate at all data area. In the constant density recording method, data area
is divided into zones by radius and the data transfer rate is set so that the
recording density of the inner cylinder of each zone is nearly constant. The drive
divides data area into 30 zones to set the data transfer rate.
The MPU set the data transfer rate setup data (SD/SC) to the RDC block that
includes the Digital PLL circuit to change the data transfer rate.
C141-E244
4.6 Read/write Circuit
4-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mhv2160bt

Table of Contents