Range Hood Controls

A
B
A. Blower speed maximum button
B. Blower speed medium button
C. Blower speed minimum button
D. Blower Off button
E. On/Off light button
Operating the light
The On/Off light button controls both lights. Press once
for On and again for Off.
Operating the blower
The Blower Speed buttons turn the blower On and control
the blower speed and sound level for quiet operation. The
speed can be changed anytime during fan operation by
pressing the desired blower speed button.
The Blower Off button turns the blower Off.

RANGE HOOD CARE

Cleaning

IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace grease
filters before operating hood.
Exterior Surfaces
To avoid damage to the exterior surface, do not use
steel wool or soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water, or all-purpose cleanser
Wipe with damp soft cloth or nonabrasive sponge,
and then rinse with clean water and wipe dry.
Metal Grease Filters
1. Remove each filter by pulling the spring release handle
and then pulling down the filter.
A
A. Spring release handle
2. Wash metal filters as needed in dishwasher
or hot detergent solution.
3. Reinstall the filter by making sure the spring release handles
are toward the front. Insert aluminum filter into upper track.
4. Push in spring release handle.
5. Push up on metal filter and release handle to latch into place.
6. Repeat steps 1 through 5 for the other filter.
C
E
D
Non-Vented (recirculating) Installation Filters
The charcoal filter is not washable. It should last up to six
months with normal use. Replace with Charcoal Filter Kit
Number W10272068.
To replace charcoal filter:
1. Cover the grille that covers the blower motor with the
charcoal filter so that the slots on the filter correspond
to the pins on the sides of the motor cover grille.
A
B
A. Charcoal filter
B. Pins
C. Blower motor
2. Turn the charcoal filter clockwise to lock it.
3. Repeat steps 1 through 2 on the other filter.
Replacing a Halogen Lamp
Turn off the range hood and allow the halogen lamp to cool.
To avoid damage or decreasing the life of the new lamp,
do not touch lamp with bare fingers. Replace lamp, using
tissue or wearing cotton gloves to handle lamp.
If new lights do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Use a flat-blade screwdriver and gently pry the
light cover loose.
3. Remove the lamp and replace with a 120-volt, 40-watt
maximum, halogen lamp made for a G-9 base.
4. Replace the light cover.
5. Reconnect power.