Power Trim Pump - Mercury INSTALLATION MANUAL D7.3L D-TRONIC Installation Manual

D7.3l d-tronic diesel engines
Table of Contents

Advertisement

Power Trim Pump

1. Mount pump in desired location.
IMPORTANT: Make hydraulic connections as quickly as possible to prevent oil from
leaking out of system. Be careful not to cross-thread or overtighten hose fittings.
d
2. Connect hydraulic hoses to trim pump. Torque fittings to 100-150 lb-in. (11-16 Nm).
3. Connect power trim pump control harness to trim pump. Secure with clamp.
4. Connect trim limit switch wires and secure with wire retainer and sta-strap.
c
75126
a
Black Hose (UP Circuit)
a -
Gray Hose (DOWN Circuit)
b -
Harness Connector
c -
Clamp
d -
Trim Limit Switch Wire (with Blue Sleeve) - to BLUE/WHITE Harness Wire
e -
Trim Limit Switch Wire (with Purple Sleeve) to PURPLE/WHITE Harness Wire
f -
Wire Retainer and Sta-Strap
g -
D7.3L D-TRONIC DIESEL ENGINES - BRAVO MODELS
b
50630
75127
f
g
50632
e
Page 31 of 90