Maintenance
item No.
Setting the Ta time-out time
U641
In the fax/telephone auto select mode, sets the time to continue ringing an operator through the connected
(cont.)
telephone after receiving a call as a fax machine (see figure 1-3-1). A fax signal is received within the Ta set
time, or the fax mode is selected automatically when the time elapses. In fax/telephone auto select mode,
change the setting when fax reception is unsuccessful or a telephone fails to receive a call.
1. Change the setting using the cursor left/right keys.
Description
Ta time-out time
2. Press the start key. The value is set.
Setting the Tb1 time-out time
In the fax/telephone auto select mode, sets the time to start sending the ring back tone after receiving a call as
a fax machine (see figure 1-3-20). In fax/telephone auto select mode, change the setting when fax reception is
unsuccessful or a telephone fails to receive a call.
1. Change the setting using the cursor left/right keys.
Description
Tb1 time-out time
2. Press the start key. The value is set.
Setting the Tb2 time-out time
In the fax/telephone auto select mode, sets the time to start ringing an operator through the connected tele-
phone after receiving a call as a fax machine (see figure 1-3-19). In the fax/telephone auto select mode,
change the setting when fax reception is unsuccessful or a telephone fails to receive a call.
1. Change the setting using the cursor left/right keys.
Description
Tb2 time-out time
2. Press the start key. The value is set.
Setting the Tc time-out time
In the TAD mode, set the time to check if there are any triggers for shifting to fax reception after a connected
telephone receives a call. Only the telephone function is available if shifting is not made within the set Tc time.
In the TAD mode, change the setting when fax reception is unsuccessful or a telephone fails to receive a call.
1. Change the setting using the cursor left/right keys.
Description
Tc time-out time
2. Press the start key. The value is set.
1-3-60
Description
Setting range
1 to 255
Tb1
Tb2
Figure 1-3-19 Ta/Tb1/Tb2 time-out time
Setting range
Initial setting
1 to 255
20
Setting range
Initial setting
1 to 255
80
Setting range
1 to 255 s
Service Manual
Initial setting
30
Ta
Change in value per step
100 ms
Change in value per step
100 ms
Initial setting
60