Maintenance
item No.
Setting the transmission system 1
U625
Description
Makes settings for the auto redialing interval and the number of times of auto redialing.
Purpose
Change the setting to prevent the following problems: fax transmission is not possible due to too short redial
interval, or fax transmission takes too much time to complete due to too long redial interval.
Start
1. Press the start key.
2. Select the item to be set.
Display
INTERVAL
TIMES
Setting the auto redialing interval
1. Change the setting using the cursor left/right keys.
Description
Redialing interval
2. Press the start key. The value is set.
Setting the number of times of auto redialing
1. Change the setting using the cursor left/right keys or numeric keys.
Description
Number of redialing
When set to 0, no redialing is performed.
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Y111030-4
Description
Description
Setting the auto redialing interval
Setting the number of times of auto redialing
Setting range
1 to 9 (min.)
Setting range
0 to 15
Service Manual
Initial setting
3 (120 V)/2 (220-240 V)
Initial setting
2 (120 V)/3 (220-240 V)