2JN
5. Remove the connector.
6. Remove the screw and then remove the
inverter PWB.
7. Check or replace the inverter PWB and refit
all the removed parts.
Caution: Replace F1 with a fuse rated 250 V
ac, 0.75 A, non-time delay, (when F1 fuse is
replaced.)
8. Unhook three hooks and then remove the
ISU reflector.
9. Remove the exposure lamp from the hold-
ers.
10. Check or replace the exposure lamp and
refit all the removed parts.
1-5-28
F1
CN1
Inverter PWB
ISU reflector
Exposure lamp
Holder
Service Manual
Inverter PWB
Connector
Figure 1-5-41
Hook
Hook
Hook
Figure 1-5-42
Lamp mount
Figure 1-5-43
Screw
Holder
Y111030-4