Olivetti d-Copia 284MF Service Manual page 48

Hide thumbs Also See for d-Copia 284MF:
Table of Contents

Advertisement

2JN
Maintenance
item No.
Adjusting the scanner center line
U067
Description
Adjusts the scanner center line of the original scanning.
Purpose
Make the adjustment if there is a regular error between the center lines of the copy image and original.
Adjustment
1. Press the start key.
2. Select the item to be adjusted using the cursor up/down keys.
Display
FRONT
ROTATE
3. Press the system menu/counter key.
4. Place an original and press the start key to make a test copy.
5. Press the system menu/counter key.
6. Change the setting value using the cursor left/right keys or numeric keys.
For copy example 1, decrease the value. For copy example 2, increase the value.
7. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
U067
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-20
Description
Scanner center line
Scanner center line (rotate copying)
Scanner center line
Original
U403
U072
(P.1-3-42)
(P.1-3-25)
Service Manual
Description
Setting
range
-70 to 70
-40 to 40
Copy
Copy
example 1
example 2
Figure 1-3-8
U404
(P.1-3-43)
Initial
Change in
setting
value per step
0
0.085 mm
0
0.085 mm
Y111030-4