Olivetti d-Copia 284MF Service Manual page 147

Hide thumbs Also See for d-Copia 284MF:
Table of Contents

Advertisement

Error code
U01154
A DCN signal was received after transmission of an RNR signal (ECM).
U01155
A DCN signal was received after transmission of an SPA signal (short protocol).
U01160
During message reception, transmission time exceeded the maximum transmission time per line.
U01161
Number of error lines exceeded limits during message reception.
U01162
A break in loop current was detected during message reception.
U01163
Polarity reversal was detected during message reception.
U01164
One page length exceeded the specified length during message reception.
U01170
A decoding error occurred during MMR message reception.
U01172
During reverse polling in V.34 mode at the transmitting unit, a JM signal was not detected after
transmission of a CM signal when receiving after transmission.
U01191
Communication was interrupted because an error occurred during an image data reception
sequence in the V.34 mode.
U01199
A DIS signal with different FIF was received after transmission of a DIS signal.
Y111030-4
Description
Service Manual
2JN
1-4-29