Preferred Symbology; High Priority Symbology; Low Priority Symbology - Honeywell Vuquest 3310g User Manual

Area-imaging scanner
Hide thumbs Also See for Vuquest 3310g:
Table of Contents

Advertisement

Left of Centering Window

Preferred Symbology

The scanner can be programmed to specify one symbology as a higher priority over other symbologies in situations where both
bar code symbologies appear on the same label, but the lower priority symbology cannot be disabled.
For example, you may be using the scanner in a retail setting to read U.P.C. symbols, but have occasional need to read a code
on a drivers license. Since some licenses have a Code 39 symbol as well as the PDF417 symbol, you can use Preferred Sym-
bology to specify that the PDF417 symbol be read instead of the Code 39.
Preferred Symbology classifies each symbology as high priority, low priority, or as an unspecified type. When a low priority
symbology is presented, the scanner ignores it for a set period of time (see
it searches for the high priority symbology. If a high priority symbology is located during this period, then that data is read imme-
diately.
If the time-out period expires before a high priority symbology is read, the scanner will read any bar code in its view (low priority
or unspecified). If there is no bar code in the scanner's view after the time-out period expires, then no data is reported.
Note: A low priority symbol must be centered on the aiming pattern to be read.
Scan a bar code below to enable or disable Preferred Symbology.
Preferred Symbology On

High Priority Symbology

To specify the high priority symbology, scan the High Priority Symbology bar code below. On the
page A-1, find the symbology you want to set as high priority. Locate the Hex value for that symbology and scan the 2 digit
hex value from the Programming Chart (inside back cover). Scan Save to save your selection. Default = None

Low Priority Symbology

To specify the low priority symbology, scan the Low Priority Symbology bar code below. On the
A-1, find the symbology you want to set as low priority. Locate the Hex value for that symbology and scan the 2 digit hex
value from the Programming Chart (inside back cover).
3 - 16
Preferred Symbology Time-out
Default = Preferred Symbology Off.
High Priority Symbology
Right of Centering Window
on page 3-17) while
* Preferred Symbology Off
Symbology Charts