Replacing an Interface Cable

1. Turn the power to the host system OFF.
2. Disconnect the scanner's cable from the terminal or computer.
3. Rotate the two screws counter clockwise to loosen the screws.
4. Gently pull the connector.
5. Replace with the new cable.
Insert the connector into the socket on the 3310. Rotate the two screws
clockwise to tighten.

Troubleshooting a Corded Scanner

The scanner automatically performs self-tests whenever you turn it on. If your scan-
ner is not functioning properly, review the following Troubleshooting Guide to try to
isolate the problem.
Is the power on? Is the aimer on?
If the aimer isn't illuminated, check that:
• The cable is connected properly.
• The host system power is on (if external power isn't used).
• The button works.
Is the scanner having trouble reading your symbols?
If the scanner isn't reading symbols well, check that the symbols:
• Aren't smeared, rough, scratched, or exhibiting voids.
• Aren't coated with frost or water droplets on the surface.
• Are enabled in the scanner or in the decoder to which the scanner connects.
Is the bar code displayed but not entered?
The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or
the Tab key, for example).
• You need to program a suffix. Programming a suffix enables the scanner to output the bar code data plus the key you
need (such as "CR") to enter the data into your application. Refer to
information.
Does the scanner read the bar code incorrectly?
If the scanner reads a bar code, but the data is not displayed correctly on the host screen:
• The scanner may not be programmed for the appropriate terminal interface.
For example, you scan "12345" and the host displays "@es%."
Reprogram the scanner with the correct Plug and Play bar code. See
• The scanner may not be programmed to output your bar code data properly.
For example, you scan "12345" and the host displays "A12345B."
Reprogram the scanner with the proper symbology selections. See
The scanner won't read your bar code at all.
1. Scan the sample bar codes in the back of this manual. If the scanner reads the sample bar codes, check that your bar
code is readable.
Verify that your bar code symbology is enabled (see
2. If the scanner still can't read the sample bar codes, scan
If you aren't sure what programming options have been set in the scanner, or if you want the factory default settings
restored, refer to
Activate Custom Defaults
13 - 2
Chapter
Chapter
7).
All Symbologies
on page 1-4.
Prefix/Suffix Overview
on page 4-1 for further
Programming the Interface
7.
On, page 7-1.