Continuous Bar Code Read
Parameter # F1h 89h
Enable this to report every bar code while the trigger is pressed.
NOTE Zebra strongly recommends enabling
accidental decodes when more than one bar code is in the imaging engine's field of view.
*
Disable Continuous Bar Code Read
(00h)
Unique Bar Code Reporting
Parameter # F1h D3h
Enable this to report only unique bar codes while the trigger is pressed. This option only applies when
Continuous Bar Code Read
*
Disable Continuous Bar Code Read Uniqueness
(00h)
Picklist Mode
is enabled.
User Preferences & Miscellaneous Options 4 - 25
with this feature. Disabling Picklist Mode can cause
Enable Continuous Bar Code Read
(01h)
Enable Continuous Bar Code Read Uniqueness
(01h)