Multifunction Mode Triggering (DS9808-LR/LL Only)
NOTE Multifunction Mode Triggering is only available in the dual-engine (imager and laser) models of the digital
scanner.
You can set trigger options for each of the digital scanner's trigger positions. For example, set Trigger A (pressed
with your index finger) to imager decoding, set Trigger B (pressed with your middle finger) for laser decoding, and
set Trigger A + B (pressed with both fingers) to RFID reading.
The default operation is single trigger, so if you do not assign values to each trigger option (or assign Trigger A
only), Trigger B operates the same as Trigger A, and a dual trigger pull is ignored.
Select one of the following functions for each trigger using the bar codes on the next few pages:
•
Laser Preferred Decoding - Programs the trigger for decoding using the laser engine first, then the imager
if a decode does not occur. See
•
Imager Decoding - Programs the trigger for decoding using the imager engine.
•
RFID Reading - Programs the trigger for reading RFID tags.
•
Imager Plus RFID - A trigger pull attempts decode using the imager engine, and turns on the optional RFID
reader, if available, to read RFID tags.
•
Laser Preferred Plus RFID - A trigger pull attempts decode using the laser engine first, then the imager if a
decode does not occur, and also turns on the optional RFID reader, if available, to read RFID tags.
•
Laser Only Decoding - Programs the trigger for decoding using the laser engine only.
•
Set to Trigger A Value (Trigger B Only) - Sets Trigger B to the same value as Trigger A. This allows you to
automatically program Trigger B upon selecting the function of Trigger A.
•
Ignore Dual Trigger Pull (Trigger A+B Only) - Uses the mode of the first trigger pull only. This increases
triggering efficiency when the dual trigger is not needed.
Trigger Locations
Figure 4-2
User Preferences & Miscellaneous Digital Scanner Options 4 - 19
Scanning on page 2-5
Trigger A
Trigger B
for more information.