Panasonic CS-E9RKUAW Service Manual page 7

Hide thumbs Also See for CS-E9RKUAW:
Table of Contents

Advertisement

Model
Indoor Operation Range
(Cooling) (°F / °C)
Outdoor Operation Range
(Cooling) (°F / °C)
Indoor Operation Range
(Heating) (°F / °C)
Outdoor Operation Range
(Heating) (°F / °C)
1.
Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Specifications are subjected to change without prior notice for further improvement.
Indoor
Outdoor
DRY BULB
Maximum
89.6 / 32
Minimum
60.8 / 16
Maximum
114.8 / 46
Minimum
0 / -17.8
Maximum
86.0 / 30
Minimum
60.8 / 16
Maximum
75.2 / 24
Minimum
-4 / -20
CS-E9RKUAW
CU-E9RKUA
WET BULB
73.4 / 23
51.8 / 11
78.8 / 26
- / -
- / -
- / -
64.4 / 18
-5.8 / -21
7
CS-E12RKUAW
CU-E12RKUA
DRY BULB
WET BULB
89.6 / 32
73.4 / 23
60.8 / 16
51.8 / 11
114.8 / 46
78.8 / 26
0 / -17.8
- / -
86.0 / 30
- / -
60.8 / 16
- / -
75.2 / 24
64.4 / 18
-4 / -20
-5.8 / -21