Fetco CBS-2131XTS User Manual page 8

Hide thumbs Also See for CBS-2131XTS:
Table of Contents

Advertisement

Programming
GENERAL
Tank Temp.
"OFF" allows
Brew at Temp.
brewing at any
temperature.
• Temperature
Units of Meas.
• Volume
ECO Mode
Logo Timeout
Brew B. Sensor
Use Flowjet
Normal for most water
LLC Sensitivity
"HIGH" for R.O.
BREW AT TEMPERATURE DEFINITONS
BREW AT TEMP: "ON"
(DEFAULT: FACTORY PROGRAMMED INTO BREWER)
"BREW START" Batch Section Buttons will not be accessible until
tank temperature is at set point.
The "BREW START" screens with the Batch Section Buttons
become accessible when hot water tank is at the selected
temperature. The screen at right displays when the "BREW AT
TEMP" is selected.
BREW AT TEMP: AUTO
This allows the "BREW START" to activate if the hot water tank is
at the selected temperature—then brew will start.
If the temperature is too low, the brewer will wait until the proper
temperature is reached. A screen (example to the right) will
display showing a thermometer icon and the tank temperature.
IMPORTANT: ALWAYS have dispenser(s) under the brew
baskets when in the BREW AT TEMP mode.
BREW AT TEMP: OFF
Allows brewing at any temperature above 179°F/82°C. (Not recommended)
Programming
INPUTS
• Input Summery
Display Inputs
Cal. Touch Screen
Factory set
Items
Default
200°F
"ON"
°C or °F
Gallons [Liters]
Energy Saving
OFF
Mode
0:30 mm:ss
NORMAL
NO
NORMAL
USER SELECTABLE
USER SELECTABLE
Factory set
Items
Default
Calibrate
Programming Range
(display)
200 °F
|______________[]___|
170
ON
|________[]_______|
OFF
ON AUTO
°F
|___[]____________|
°F
°C
Gallons
|___[]____________|
Gallons
Liters
ECO Mode
_______________[]_____
ON
OFF
0:30 mm:ss
|__[]___________|
0:15
NORMAL
|__[]____________|
NORMAL
OVERRIDE
NO
____[]_______________
NO
YES
NORMAL
____[]______________
NORMAL
[ft]
XTS
0
EXTRACTOR
500
TOUCHSCREEN
CBS_2132 3L
1000
Ready
Tank Temp °F
197
2000
Heating
2500
Filling
XTS
3000
3500
Regular 1
1.50
INFO
4000
05:30
Regular 2
4500
1.50
05:30
5000
Decaf 1
92°
1.50
5500
05:30
C
Decaf 2
6000
STOP
1.00
05:30
6500
7000
7500
8000
8500
Programming Range
(display)
R. Brew Basket Sens. [ single/dual]
L. Brew Basket Sens.
H. Liquid Level probe
H. Tank Temperature Probe
L. Tank Temperature Probe
SD Card Recognized
Tank Temp.
200
Calibrate
________________[]____
YES
8
Notes
Correction for high
altitude below
207
SEE NOTE BELOW!
[Switchable Units]
[Switchable Units]
If Selected: Lowers hot
water tank temperature to
170°F after 1 hour of
inactivity
5:00
Factory or service use for
servicing. "NORMAL" is
recommended for safety.
Trims water handling
system for Flowjet
Sets sensitivity for liquid
level control.
High is for reverse osmosis
water or other very pure
HIGH
water.
Chart to correct for altitude for boiling point
in tank water temperature.
Suggested
Boiling
Suggested
[m]
Setting[°F]
point[°F]
Setting[°C]
0
200
212.0
152
200
211.0
305
200
210.1
610
200
208.1
762
200
207.2
914
200
206.2
1067
197
205.3
1219
195
204.3
1372
194
203.4
1524
194
202.4
1676
193
201.5
1829
192
200.6
1981
191
199.6
2134
190
198.7
2286
188
197.8
2438
187
196.9
2591
185
196.0
Notes
If Yes:
Follow directions on the
touch screen
NO
Boiling
point [°C]
93
100.0
93
99.5
93
98.9
93
97.8
93
97.3
93
96.8
92
96.3
91
95.7
90
95.2
90
94.7
89
94.2
89
93.6
88
93.1
87
92.6
86
92.1
86
91.6
85
91.1