5. Film is jammed on the rollers.
a. Un-jam the film using a combination of the pressure lever and reverse button.
6. Disconnected motor wire.
a. Check the motor wire connection in both locations.
7. Blown motor fuse.
a. Replace the motor fuse located above the main power switch.
8. Defective main motor.
a. Replace the main motor.
9. Defective main PCB.
a. Replace the main PCB.
Motor wire connector
from the Motor
Motor wire connector
from the PCB
Motor Fuse
9