Sam Cab Fault; Progressive Low Voltage Disconnect; Sam Chassis Fault - freightliner cascadia Driver Manual

Table of Contents

Advertisement

02/07/2007

SAM Cab Fault

If the emergency power supply system activates, do
not shut down the engine until the vehicle is in a safe
position to do so. It will not be able to be restarted
until the problem is corrected. If emergency power
mode is due to a SAM Cab fault, the gauges will be-
come unresponsive but the engine will remain run-
ning until it is turned off.
When the ignition is in the ON position, the emer-
gency power supply will cause the following lamps to
flash:
dash panel lights
clearance lights
front marker lights
side marker lights
trailer taillights
rear stop lights

SAM Chassis Fault

The engine may be able to be restarted when the
SAM Chassis fails. When the ignition is in the ON
position, the emergency power supply will cause the
following lamps to flash:
dash panel lights
Fig. 3.4, SAM Cab Location
identification lights
front marker lights
turn-signal indicators in the ICU (alternately)
side marker lights
rear turn-signal lights
trailer taillights
If the ignition switch is turned ON while the load dis-
connect switch is in the OFF position, the emergency
power supply feature will activate the following
lamps:
clearance lights (flashing)
side marker lamps (flashing)
low beam headlights
Progressive Low Voltage
Disconnect
The progressive low voltage disconnect (PLVD) fea-
ture protects the batteries from excessive discharge
by disconnecting certain circuits from battery power
supply. This allows the batteries to maintain accept-
able charge to restart the vehicle.
When battery voltage drops below a predetermined
value, loads designated as comfort loads (priority
Electrical System
f544945