3.
Disassembly & Reassembly Procedures
3.1

Introduction.

replaceable units.
Whenever a unit is replaced, mechanical and functional testing as
described in Section 2 must be completed.
3.2
F3 Tool Kit. The F3 Tool Kit (Part No 3004-0018) is required to disassemble and
reassemble the F3. The tool kit (Figure 9) comprises:
Minelab Part No
0005-0014
0005-0010
8701-0009
8701-0010
8701-0011
8701-0018
8701-0012
8701-0013
All tools except the F3 Coil Cable Pull Through are commercially available. If necessary, a
length of string can be used as the F3 Coil Cable Pull Through.
3.3
Electronics Pack. Figure 10 illustrates the major parts involved in removing and
replacing the electronics pack. The F3 and F3L use different electronics packs and should
not be interchanged unless the correct speaker pods (F3L requires the speaker pod with
LED display) are also fitted.
F3 Field Service Manual
This section describes the procedures required to exchange line
Description
Silicon Grease (100g tube)
Silicon Sealant (75g tube)
Tubular Spanner 7/8"
F3 Coil Cable Pull Through
Screwdriver Pozidrive No 1
Hex Key T Handle 2.5mm
Hex Key T Handle 3.0mm
Flat blade screwdriver 6.5mm x 150mm
Figure 9: F3 Tool Kit