DSC Maxsys PC4020 System Manual page 23

Hide thumbs Also See for Maxsys PC4020:
Table of Contents

Advertisement

Item [0], [1], [5] and [6] turn on and off various functions.
To enable or disable these functions, press the [ ] key to
toggle "Y "or "N" on the keypad.
Y - The function is enabled
N - The function is disabled
Quick Arm
[ ] [6] [Access Code] [0]
The "Quick Arm" feature is enabled by toggling to "Y" on
the keypad. When enabled the panel can be armed by
entering [ ][0]. Users with a One Time Use access code
should not use this feature because the OTU code is only
erased when used to arm.
Quick Exit
[ ] [6] [Access Code] [1]
The "Quick Exit" function is enabled by toggling to "Y" on
the keypad. When enabled the user can exit through any
delay zone without altering the status of the system, by
entering [ ]+[0] on the keypad while the system is armed.
Note: Quick Exit must not be enabled on UL listed
systems.
Auto Arm Control
[ ] [6] [Access Code] [2]
The Auto Arm Control options can only be accessed if
Auto Arm is enabled for the partition. The PC4020 can be
programmed to arm a partition at the same time each day,
by enabling the Auto Arm function and programming the
Auto Arm time.
At the selected Auto Arm time, the system will give a pre-
alert. The keypad buzzer begins to sound and the Bell/
Siren will pulse once every 10 seconds to alert anyone on
the premises that the system is about to arm. The Bell/
Siren pulse can be disabled in Installer's Mode.
The keypad buzzer will sound for one minute before Auto
Arming unless the Auto Arm is aborted. To abort the Auto
Arm and silence the keypad press any key during the pre-
alert. The Auto Arm will be attempted at the same time the
following day. The PC4020 can be programmed to require
a code to be entered for a user to abort the Auto Arm.
Upon selecting the Auto Arm Control function, the Auto
Arm Control menu will appear on the LCD keypad.
[0] Auto Arm
[1] Schedule Arm
[3] Sched Disarm
[0] Auto Arm toggles "Y" or "N" to enable or disable the
Auto Arm/Auto Disarm function.
[1] Schedule Arm when this toggle option is enabled the
partition will follow the Auto Arm schedule programmed
(by the installer) for that partition. When this option is
enabled the partition will not follow the Auto Time
(programmed in section 2). For the Auto Arm Time to
function this option must be disabled.
[2] Auto Arm Time is the time the partition will
automatically arm itself every day.
[3] Sched. Disarm when this toggle option is enabled the
partition will follow the Autodisarm schedule programmed
(by the installer) for that partition.
Note: The Auto Arm time is a 24 hour clock and times
must be entered as two digit numbers.
E.g. HH - 00, 01,.....10, 11,.....22, 23
Enter 4 digits representing the time in hours and minutes
(HH:MM) based on 24 hour or military time. Always enter a
leading zero where only one digit is required, 8:05 am would
be entered as 0805, 1:30 pm would be entered as 1330.
Note: The panel will not autoarm, schedule arm, or
schedule disarm, if there is a loss of time trouble
present on the system.
Keypad Setup
[ ] [6] [Access Code] [3]
This function allows the user to adjust the backlighting and
contrast of each LCD4500 keypad. When this function is
selected, the Keypad Setup menu will appear on the keypad.
• Bright Control adjusts the level of backlighting on
• Contrast Control adjusts the contrast of the lettering
Use the [<][>] keys to toggle through the eight different
settings, and press [ ] to select the level of preference.
Note: To adjust the keypad brightness and contrast
control of a global keypad, the keypad must first be
loaned to a partition.
Bell/Comm Test
[ ] [6] [Access Code] [4]
This option allows the end user to test the system. This
option activates all outputs programmed for 'Fire and
Burg', 'Inv Fire/Burg', 'Burg Only' and 'Inv Burg Only' for
two seconds, sounds the keypad's for 2 seconds, tests
the main board and PC4204 battery voltage, and sends a
test code transmission to the monitoring station.
Door Chime
[ ] [6] [Access Code] [5]
[2] Auto Arm Time
The Door Chime feature is enabled or disabled on a
partition by pressing the [ ] key to toggle from "N" to "Y"
or "Y" to "N". When the door chime feature is enabled,
any zone that has been selected as chimeable will cause
the keypad to beep 5 times each time the zone opens or
restores while the partition is disarmed (Note that Fire
zones and 24 hour zones are never disarmed, therefore
they can never chime).
See "Chime Function" in the Programming Manual to
enable a zone to use the chime function. While disarmed
zone bypass may be used to eliminate the beeping.
21
MM - 00, 01,.....35, 36.....58, 59
the LCD display and the backlighting on the keys.
on the LCD display.

Advertisement

Table of Contents
loading

Table of Contents