Download Print this page

Electrical Connections; Service/Parts Information - Maytag 8101P668-60 Installation Instructions Manual

Maytag cooktop user manual

Advertisement

ELECTRICAL CONNECTIONS

This unit should be properly protected and wired according to
local electrical code and National Electrical Code.
It is advisable that a competent electrician should accomplish the
electrical wiring and hookup.
120/240 VAC or 120/208 VAC 60Hz. See serial plate located under
the range top control panel on this unit for power requirements.
The neutral of this unit is grounded to the frame through the solid
grounding wire. (The ground and the white wires are twisted
together at the termination of the conduit.) If used on new
branch-circuit installations (1996 NEC), mobile homes,
recreational vehicles, or in an area where local codes prohibit
grounding through the neutral conductor, untwist or disconnect
the ground wire and connect to ground in accordance to local
code. Connect the white neutral to the service neutral. Connect all
wires to the branch circuit with approved connectors. Use copper
or aluminum wire. If aluminum wire is used, use connectors
recognized for joining aluminum to copper.
The chart to the right recommends the minimum circuit
protection and wire size if the appliance is the only unit on the
circuit.
HOW TO REMOVE RANGE FOR SERVICING
Follow these procedures to remove appliance for servicing:
1. Slide range forward to disengage range from the anti-tip bracket.
2. Disconnect electrical supply to appliance, if equipped.
3. Reverse procedure to reinstall.
4. To prevent range from accidentally tipping, range must be secured
to the floor by sliding rear leveling leg into the anti-tip bracket.
SERVICE-PARTS INFORMATION
When your range requires service or replacement parts, contact your dealer or authorized service agency. Please give the complete model
and serial number of the range which is located on front frame behind storage drawer.
Your range may not be equipped with some of the features referred to in this manual.
Serial Plate
RECOMMENDED MINIMUM
K.W. RATING
CIRCUIT PROTECTION
ON SERIAL PLATE
0 - 4.8
4.9 - 6.9
7.0 - 9.9
10.0 - 11.9
Plaque signalétique
12.0 - 14.9
W A R N I N G
DISCONNECT ELECTRICAL SUPPLY BEFORE SERVICING
THE APPLIANCE.
WIRE SIZE
IN AMPERS
(AWG)
20
12
30
10
40
50
60
8
8
6

Advertisement

loading

This manual is also suitable for:

Mep5775baMep5775baf - 30in electric range