Instruction manual 550-532 - 00.0 - 07/2015
• To increase pressure: Turn the pressure controller (2)
clockwise.
• To reduce pressure: Turn the pressure controller (2)
counterclockwise.
3.
Push the pressure controller (2) down.

10.3.2 Checking water condensation

NOTICE
Machine damage possible if there is too much water.
Too much water can result in damage to the machine.
Check the water level every day and drain the water
condensation if there is too much water in the water
separator.
Water condensation will accumulate in the water separator of the
maintenance unit.
Fig. 38: Checking the water condensation in the water separator
(3) - Filter element
(4) - Water separator
Checking the water level
1.
Check the water level in the water separator (3) on a daily
basis.
Important: Water condensation must not rise up to the level of
the filter element (2).
(5) - Drain screw