Monitoring Chassis Temperature; Monitoring Chassis Temperature Status; Temperature Errors - Alcatel-Lucent OmniSwitch 10K User Manual

Hide thumbs Also See for OmniSwitch 10K:
Table of Contents

Advertisement

Monitoring Chassis Temperature

Monitoring Chassis Temperature
The operating temperature of your switch is a critical factor in its overall operability. In order to avoid a
temperature-related system failure, your switch must always run at a temperature within the specified
operating temperature range. Refer to the
To avoid chassis over-temperature conditions, follow the important chassis airflow recommendations on
page
2-7.

Monitoring Chassis Temperature Status

To check the switch's current temperature status, use the
-> show temperature
Device | Current |
-------+---------+---------+--------+--------+-----------------
CMMA
45
CMMB
45
FABA
46
Slot1
43
Slot3
43
Slot4
43
Note: All temperatures are in Celsius.
For more information about this command, see the "Chassis Management and Monitoring Commands"
chapter in the OmniSwitch CLI Reference Guide.

Temperature Errors

The CMM monitors the chassis ambient air temperature at all times via an onboard sensor. If an over-
temperature condition occurs, there are two different levels of error severity:
Warning threshold has been exceeded
Danger threshold has been exceeded
page 2-26
page 2-3
Range
| Danger | Thresh |
15-73
73
15-73
73
15-73
73
15-73
73
15-73
73
15-73
73
for more information.
show temperature
Status
68
UNDER THRESHOLD
68
UNDER THRESHOLD
68
UNDER THRESHOLD
68
UNDER THRESHOLD
68
UNDER THRESHOLD
68
UNDER THRESHOLD
OmniSwitch 10K Hardware Users Guide
Chassis and Power Supplies
command. For example: