Invacare® TDX SP2® Series
7.
Remove the terminal cover from the battery terminals (1).
8.
First undo the bolt on the negative terminal (black cable) with
the 11 mm jaw spanner.
9.
After this, undo the bolt on the positive terminal (red cable).
CAUTION!
Risk of crushing
– The batteries are extremely heavy. Please ensure that
they do not fall to the ground when they are removed
from the chassis.
10. Installation takes place in reverse order.
11. Check all vehicle functions.
12. Check the new battery status and charge completely.
76
1578997-A