14. SOFT SWITCH SET
14.3.4

SOFT SWITCH: #04

Bit No.
Designation
8
7
Reserved
6
5
Visible alarm for RTN
4
signal
Audible alarm for RTN
3
signal
2
Pulse shape
1
• Bit 4: The display message will keep on LCD 3 seconds or until next incoming T30 sig-
nal.
• Bit 3: The duration of alarm last 3 second after detect negative signal in G3 mode.
216
Function
Reserved
0: No
1: Yes - Display message while sending / receiving
RTN signal (RTN= Retrain Negative).
0: No
1: Yes - Alarm (BZ-42) for sending or receiving RTN
signal.
Normal
Bit No. 2
0
Bit No. 1
0
Field Service Ver. 1.1 May 2011
Super slow
Slow shape
shape
0
1
1
0
Initial
setting
Bit
HEX
0
0
0
0
0
1
1
C
0
0

Hide quick links: