28 INSTALLATION
INSTRUCTIONS
Installation
Test
(Duct
check)
(cont.)
• Check the error code before you call for service
Error Code
Possible Causes
,
Solutions
, Temperature
sensor failure
tl:l or tl:2
HS
, Humidity
sensor failure.
• Electric dryer power cord is not
connected
correctly, or house power
supply is incorrect.
• House fuse is blown, circuit breaker has
tripped, or power outage has occurred.
PS or PF or nP
• Turn off the dryer and call for
service.
• Turn off the dryer and call for
service.
• Check the power supply or the
connection of power cord to the
terminal block. Referto the
Connecting electric dryers section of this manual
for complete instructions.
• Reset circuit breaker or replace fuse. Do not increase
the fuse capacity.
If the problem is a circuit overload, have it corrected
by a qualified electrician.
• Check the duct condition
If the test displays four bars, check the exhaust system
for restrictions
and damage. Repair or replace the
exhaust system as needed.
_-----
_
NOTE
When the dryer is first installed, this test should be
performed
to alert you to any existing problems
with
the exhaust duct in your home. However, since the
test performed
during
normal operation
provides
more accurate information
on the condition
of the
exhaust duct than does the installation
test, the
number of bars displayed
during the two tests may
not be the same.
Do not interrupt
the test cycle, as this could result in
the wrong
results.
Even if no bars are displayed
during the test cycle,
some restrictions
may still be present in the exhaust
system. Refer to the Venting
the Dryer section of
this manual for complete
exhaust system and venting
requirements.
Your dryer features Flow Sense
TM,
an innovative
sensing system that automatically
detects blockages
and restrictions
in dryer ductwork.
Keeping ductwork
clean of lint buildup
and free of restrictions
allows
clothes to dry faster and reduces energy use.
J
Restricted
or blocked
airflow
[]
Avoid long runs or runs with multiple
elbows
or
bends.
Excess or crushed
Too many elbows
or
transition
duct
exhaust
too long
Check for blockages and lint buildup.
Lint buildup
or blockage
Make sure the ductwork
is not crushed or restricted.
,j_J
_[_
Crus_hed
or
damaged
exhaust