Download Print this page

LG DLGX5681V Owner's Manual page 25

Hide thumbs Also See for DLGX5681V:

Advertisement

Available languages

Available languages

INSTALLAiTION
INSTRUCTIONS
25
Connecting
Elecfric
Dryers
(conf.)
USA
only
_WARNING
• Connect the power cord to the terminal
block.
Connect each power cord wire to the terminal
block
screw that has the same colored wire. For example,
connect the black power cord wire to the terminal
block screw with
the black wire. Failure to follow
these instructions
may result in a short, overload,
fire or death.
• Grounding
through
the neutral conductor
is
prohibited
for: (1 } new branch-circuit
installations,
(2) mobile
homes,
(3) recreational
vehicles, and
(4) areas where local codes prohibit
grounding
through
the neutral
conductor.
Three-wire
connection
for electric dryers: Direct wire
• A 3-wire connection is NOT permitted
on new
construction after January 1, 1996.
• A ULqisted strain relief is required.
1
1. Remove 3/2 inches (8.9 cm) of the outer covering from
the wire. Strip 1 inch (2.5 cm) insulation
from each
wire. Bend the ends of the three wires into a hook
shape.
1" (2,5 cm)
I-q
. Use UL-listed
3-wire #10 AWG-minimum
copper
conductor
cable.
. Allow at least S ft. (1 .S m) length to allow for removal
and reinstallation
of the dryer.
3. Attach the two hot leads of the power cord to the
outer terminal
block screws. Attach the neutral wire to
the center terminal
block screw. Connect the external
ground
(if required by local codes) to the green
ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstal] the terminal
block access cover.
Neutral
Hot
(White)
(Black)
|
Ground
Hot
Screw.
I
_,_I_
(Red)
Wire (If required
by local codes)
2. Remove the terminal
block access cover on the upper
back of the dryer. Install a UL-listed strain relief into
the power cord through-hole;
then thread the power
cable prepared in Step 1 through
the strain reliefl
Block
Li2t; 1,of
Uk-Listed
3-Wire
/
Power Cord

Advertisement

loading

This manual is also suitable for:

Dlex5680vDlgx5681wDlex5680w