About Connectors

Auto Adjustment Time Function Connection 2

When settings menu - [Basic] - [Time & date] - [Auto adjustment time] is set to [Slave]
[Time Adjust Input] is available and the time on the recorder is synchronized with the other devices.
15 minutes before or after the set [Activation time] if a signal output from another device is input to the Adjustment Time I/O, the time on the
recorder is set to the [Activation time].
Example:
When the [Activation time] is set to 15:00
• A signal is received at 2:50:00 pm → Set to 3:00:00 pm
• A signal is received at 3:14:45 pm → Set to 3:00:00 pm
• A signal is received at 3:20:00 pm → Time is not adjusted.
Important:
When [Auto adjustment time] is set to [Slave], time adjustment is not performed during emergency recording and event recording.

Connectivity for Control Output

Connecting alarm equipment like the buzzer and indicator to pins 15 to 18 sounds the buzzer, lights the indicator and indicates operating status
when a signal is output.
An example of HDD error output (pin 16) is shown below.