Epson Stylus Photo R280/R285/R290/Epson Artisan 50/Epson Stylus Photo T50/T59/T60/P50
Occurrence
Symptom
Timing
• The CR Unit hits
against the Change
Lever which has come
down toward the front
of the printer.
• The error appears after
At power-on
the PF roller makes
quick one-turn.
The CR Unit hits
against the Upper Paper
Guide detached from
the Main Frame.
Chapter 3 Troubleshooting
Table 3-5. Troubleshooting for Fatal Error
Failed Part
1. Is the Compression spring 2.36 of the Change
Lever disengaged?
ASF Unit
Compression Spring2.36
1. Is the PF motor cable not connected to CN13 on
the Main Board?
PF Motor
2. Is there a malfunction of the PF motor?
1. Is the PF encoder FFC not connected to the PF
encoder connector and the Main Board?
PF Encoder
2. Is the PF encoder chipped or broken?
1. Is the PF Scale not moving freely, centered
between the sides of PF encoder sensor?
PF Scale
2. Is their any dirt on the PF Scale?
3. Is the PF Scale chipped or broken?
1. Is the Upper Paper Guide detached from the Main
Frame?
Upper Paper Guide
3.3 Troubleshooting by Error Message
Check Point
1. Replace the ASF Unit.
CR Motor
Change Lever
1. Connect the cable to the Main Board.
2. Replace the PF motor.
1. Connect the FFC to the PF encoder and the
Main Board.
2. Replace the PF encoder.
1. Install the PF Scale or PF encoder correctly.
2. Clean off any dirt on the PF Scale. If the scale
gets heavily soiled, replace the scale.
3. Replace the PF Scale.
1. Attach the Upper Paper Guide correctly.
Remedy
Reference
4.4.14 "ASF Unit"(p.92)
4.3.1 "Main Board
Unit"(p.64)
4.4.11 "PF Motor"(p.87)
4.3.1 "Main Board
Unit"(p.64)
4.4.10 "PF Encoder / PF
Scale"(p.86)
4.4.10 "PF Encoder / PF
Scale"(p.86)
4.4.10 "PF Encoder / PF
Scale"(p.86)
4.4.15 "Upper Paper
Guide"(p.94)