Adjusting System Device Settings; Unit Configurable Settings; Edit Equipment Details - Lennox iComfort Wi-Fi Setup Manual

Touch screen programmable communicating thermostat
Hide thumbs Also See for iComfort Wi-Fi:
Table of Contents

Advertisement

Adjusting System Device Settings

1. Press any component listed under system devices
to change specific communicating equipment para­
meters and edit details of devices in the system.
2. Use the arrows to highlight a setting and then press
edit (figure 9A). In the example, the low heating air­
flow is changed from the default (400) to 325 (figure
9B). After changing, press save. (note the current
value has changed; figure 9C). Some changes may
affect other settings and, if so, those affected will
appear in red and require changing/saving to clear
the red settings.
3. When finished, press back; equipment parameters
screen then press next. Select tests to run screen
appears; either run tests as before or press skip
tests.
®
iComfort

UNIT CONFIGURABLE SETTINGS

The following tables list the system devices settings available from the installer setup screens.
System
Heat Pump
Furnace
Thermostat
9:39 am Aug 15, 2012
Equipment Name
Filter 1 Timer Selection
Filter 2 Timer Selection
UV Bulb Timer Selection
Humidifier Pad Timer Selection
PureAir Timer Selection
Smooth Setback Recovery
Electric Heat Control Mode
EvenHeat Discharge Temp
Gas Heat Control Mode
Number of Gas Heating Stages (SLP98V only) (staged selection)
Modulating Gas Heating Steady State PI (SLP98V only)
Modulating Gas Heat Step Change PI (SLP98V only)
Modulating HP Heating Cycles Per Hour (XP25 only)
Modulating HP Electric Heating Switching Point (XP25 only)
Modulating HP Heating Steady State PI Gain (XP25 only)
Modulating HP Heating Step Change PI Gain (XP25 only)
Modulating Cooling Steady State PI Gain (XC25 and XP25 only)
Modulating Cooling Step Change PI Gain (XC25 and XP25 only)
Modulating Cooling Cycles Per Hour (XC25 and XP25 only)
507343-01
Figure 9. Edit Equipment Details
Table 2. System Devices > System
system devices
Parameter Name:
System
Equipment Name
Heating Airflow Control Type
Low Heating Airflow
High Heating Airflow
High Cooling Airflow
Airflow Profile - Cooling
System
High HP Airflow
Equipment Name
Continuous Indoor Blower Airflow
Heating Airflow Control Type
Heating Indoor Blower OFF Delay
Low Heating Airflow
High Heating Airflow
9:39 am Aug 15, 2012
High Cooling Airflow
Airflow Profile - Cooling
High HP Airflow
Continuous Indoor Blower Airflow
Heating Indoor Blower OFF Delay
9:39 am Aug 15, 2012
To adjust a setting,
highlight it, then
press Edit
System
back
Default
Calendar Time
Calendar Time
Calendar Time
Calendar Time
Calendar Time
Enabled
Standard
85ºF
Staged
4
Standard
Standard
4.0
1.0
Standard
Standard
Less
Aggressive
Less
Aggressive
4.0
Page 8
Low Heating Airflow
current value:
400
Low Heating Airflow
current value:
back
325
Low Heating Airflow
Range is 325 to 450 CFM
Default is 400, inc: 25
set-to
325 CFM
back
cancel
save
about
resetAll
edit
next
Parameter Value Setting
Press edit to change name (up to 35 charac­
ters may be used).
Note: Pressing the resetALL button will re­
set all custom parameter settings back to
factory default.
Calendar Time, Run Time
Calendar Time, Run Time
Calendar Time, Run Time
Calendar Time, Run Time
Calendar Time, Run Time
Enabled, Disabled
Standard, Evenheat
85ºF to 130ºF
Staged, Variable Capacity, Load Tracking
Variable Capacity
1, 2, 3 or 4
Less Aggressive, More Aggressive, Standard
Less Aggressive, More Aggressive, Standard
3.0 to 6.0
0.0 to 2.0
Less Aggressive, More Aggressive, Standard
Less Aggressive, More Aggressive, Standard
Less Aggressive, More Aggressive, Standard
Less Aggressive, More Aggressive, Standard
3.0 to 6.0
edit
reset All
edit
Reset All
Increment
15ºF
0.5
0.25
0.5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents