Table 10. Alert Codes and Troubleshooting
Alert
PRIORITY
Code
CONDITION
19
Minor
29
Critical
30
Moderate
31
Critical
®
iComfort Wi-Fi
APPLICABLE
SYSTEM
ALERT TEXT
COMPONENTS
The outside temperature is
higher than the level where the
Thermostat
furnace or electric heat is pro
grammed to work.
The thermostat is reading an in
door temperature that is higher
than 99ºF. The thermostat will
Thermostat
not allow any heating operation
to begin until it senses an in
door temperature lower than
99ºF.
The thermostat is reading an in
door temperature that is lower
Thermostat
than 40ºF.
The thermostat has lost com
munication with a system com
Thermostat
ponent for more than three min
utes.
Critical alerts are displayed on the Home screen, in the Home
owner alert button, and in the Installer alert button. Minor and
moderate alerts are found only in the Installer alert button.
COMPONENT OR SYSTEM OPERA
TIONAL STATE AND TROU
BLESHOOTING TIP
The system will only use the heat
pump to warm your home
This is a notification only alert
code.
Outdoor temperature is above the
low balance point.
Indoor unit (furnace or air han
dler) will not be used to service a
heating demand.
Indoor temperature rose above
99ºF during a heating or cooling
demand.
Heating operation is not allowed.
Check to ensure that heating
equipment is not stuck ON (re
versing valve, etc.).
Check the accuracy of the ther
mostat temperature sensor.
Select cooling system mode to
cool the indoor space.
The thermostat will not allow any
cooling operation to begin until it
senses a temperature higher than
40ºF.
Indoor temperature fell below
40ºF.
Cooling operation is not allowed.
Check to ensure that cooling
equipment is not stuck ON.
Check accuracy of the thermostat
temperature sensor.
Select heating system mode to
heat the indoor space to above
40ºF.
The applicable system compo
nent (indoor, equipment interface
or damper control module or out
door unit) has not communicated
with thermostat for more than
three minutes.
Check connections.
Ohm wires.
7-Day Programmable Communicating Thermostat
Page 43
HOW TO CLEAR
ALERT CODE
Automatically clears
when the system de
tects that the issue no
longer exists.
Automatically clears
when the system de
tects that the issue no
longer exists.
Automatically clears
when the system de
tects that the issue no
longer exists.
If fault persists,
then cycle power.
Fault clears after
communication is
restored.