Table 10: Recommended Sta Path Costs; Table 11: Default Sta Path Costs - LevelOne GSW-4876 User Manual

48 ge + 2 ge sfp web smart switch
Hide thumbs Also See for GSW-4876:
Table of Contents

Advertisement

| Configuring the Switch
C
4
HAPTER
Configuring the Spanning Tree Algorithm

Table 10: Recommended STA Path Costs

Port Type
Link Type
Ethernet
Half Duplex
Full Duplex
Trunk
Fast Ethernet
Half Duplex
Full Duplex
Trunk
Gigabit Ethernet
Full Duplex
Trunk

Table 11: Default STA Path Costs

Port Type
Ethernet
Fast Ethernet
Gigabit Ethernet
Priority – Defines the priority used for this port in the Spanning Tree
Algorithm. If the path cost for all ports on a switch are the same, the
port with the highest priority (i.e., lowest value) will be configured as
an active link in the Spanning Tree. This makes a port with higher
priority less likely to be blocked if the Spanning Tree Algorithm is
detecting network loops. Where more than one port is assigned the
highest priority, the port with lowest numeric identifier will be enabled.
(Range: 0-240, in steps of 16; Default: 128)
Admin Edge (Fast Forwarding) – You can enable this option if an
interface is attached to a LAN segment that is at the end of a bridged
LAN or to an end node. Since end nodes cannot cause forwarding loops,
they can pass directly through to the spanning tree forwarding state.
Specifying edge ports provides quicker convergence for devices such as
workstations or servers, retains the current forwarding database to
reduce the amount of frame flooding required to rebuild address tables
during reconfiguration events, does not cause the spanning tree to
initiate reconfiguration when the interface changes state, and also
overcomes other STA-related timeout problems. However, remember
that this feature should only be enabled for ports connected to an end-
node device. (Default: Edge)
Auto Edge – Controls whether automatic edge detection is enabled on
a bridge port. When enabled, the bridge can determine that a port is at
the edge of the network if no BPDU's are received on the port.
(Default: Enabled)
Restricted Role – If enabled, this causes the port not to be selected
as Root Port for the CIST or any MSTI, even if it has the best spanning
– 136 –
IEEE 802.1D-1998
100
95
90
19
18
15
4
3
Link Type
IEEE 802.1w-2001
Half Duplex
2,000,000
Full Duplex
1,000,000
Trunk
500,000
Half Duplex
200,000
Full Duplex
100,000
Trunk
50,000
Full Duplex
10,000
Trunk
5,000
IEEE 802.1w-2001
2,000,000
1,999,999
1,000,000
200,000
100,000
50,000
10,000
5,000

Hide quick links: