7.1 Home Page
When inverter is operating normally, the LCD will display the homepage as
shown in Figure 7-4, user can get the information of output power, inverter status,
E-today, date and time.
Today Energy
Today Runtime
Inverter Status
Today Power Curve
7.2 LCD Flow Chart
Press the EXIT button to enter the menu page (Figure 7-5). The option "E-today"
is the homepage.
Power Meter
Energy Log
Event Log
Operation Data
Inverter Information
Setting
7.2.1 Power Meter
This page shows the information about input and output power.
E-Today: 47kWh
Runtime: 8.2Hrs
On Grid
20
15
10
5
0 4
8
12
Figure 7-4 Home page
7.2.1
7.2.2
7.2.3
7.2.4
7.2.5
7.2.6
Figure 7-5 Menu page
Power Meter
Input1
Input2
P
1420
1455
V
222
225
I
6.4
6.5
Today Energy:
Today Runtime:
Today Earning:
Today CO2 Saved:
Figure 7-6 Power meter page
21. Jun 2010 13:50
Power: 12103W
16
20
24
Menu
E-Today
Power Meter
Energy Log
Event Log
Operation Data
Inverter Information
Setting
21. Jun 2010 13:50
Output
1480
W
224
V
6.6
A
0
kWh
0.0
Hours
0
€
0.0
kg
Day - Time
Output Power
37