The technical instructions and illustrations in this manual are to be treated as confidential and no part of this manual may be reproduced without prior written permission from Delta Energy Systems Maintenance technicians and end users may not release the information contained in this manual,...
The solar inverter can be safely and normally operated if DANGER installed and used in accordance with this manual (see IEC 62109-5 3 3) Delta Energy Systems is not responsible Risk of death by electrocution for damage incurred by failure to observe the installation and...
Move downwards in menu Set value (decrease) Move up Move upwards in menu Set a value (increase) Select menu item. Open configurable value for editing. Enter Finish editing (adopt set value) Quick installation guide for RPI M6A M8A M10A inverters...
Quick Installation Guide RPI M6A RPI M8A RPI M10A Quick Installation Guide and AC Plug Amphenol C16-3 2 mounting screws to fasten the General Safety Instructions inverter to the mounting plate Quick installation guide for RPI M6A M8A M10A inverters...
► Consider the operating temperature range (see sec- >20 cm >20 cm >20 cm tion “Technical Data”) When the operating temperature range is exceeded, the solar inverter reduces the amount of power gener- ated Quick installation guide for RPI M6A M8A M10A inverters...
± 20% TT is not recommended The voltage of N has to L2-L3 400 V ± 20% L3-N 230 V ± 20% be very close to PE (difference < 20 V Quick installation guide for RPI M6A M8A M10A inverters...
Page 9
To do this, connect the PE conductor to the designated terminal of the AC plug The possibilities of faults were examined by Delta without tak- ing the integrated RCMU (residual-current monitoring unit) into account When examining these faults in terms of the current...
► To ensure protection degree IP65, cap all to disconnect MC4 DC connectors unused connectors with the caps delivered from the inverter Otherwise you with the inverter might destroy the DC connectors Quick installation guide for RPI M6A M8A M10A inverters...
Designation plant to a monitoring system VCC (+12 V) If you want to use SOLIVIA Monitor, the Internet based monitor- ing system from Delta, you additionally need a SOLIVIA M1 G2 DATA+ Gateway DATA– Default baud rate is 19200 which can be changed on the inverter...
No action The inverter has no fans Insulation Insulation test failed An error, fault, or warning message Alarm occurred Error An error message occurred Fault A fault message occured Warning A warning message occured Quick installation guide for RPI M6A M8A M10A inverters...
P o w e r : E - T o d a y : 0 k W h ► Check the next chapter of this quick installation guide whether you need to adjust addtional settings Quick installation guide for RPI M6A M8A M10A inverters...
B a u d r a t e 9 6 0 0 Use the buttons to select a value 1 9 2 0 0 To confi rm your setting, press the button 3 8 4 0 0 Quick installation guide for RPI M6A M8A M10A inverters...
C o n n e c t i o n t y p e : To confi rm your selection, press the button 3 P 3 W / 3 P 4 W Quick installation guide for RPI M6A M8A M10A inverters...
This setting is protected by a special password To get the password, please call the Delta Support hotline in your country. You can fi nd the telephone number on the last page of this quick installation guide.
The maximum AC apparent power indicates the power an inverter is able to deliver This maximum apparent power may not neces- sarily be reached AC voltage and frequency range will be programmed according to the individual country requirements Quick installation guide for RPI M6A M8A M10A inverters...
Page 19
IEC 61000-4-2 / -3 / -4 / -5 / -6 / -8 Harmonics EN 61000-3-2 EN 61000-3-12 Variations and flicker EN 61000-3-3 EN 61000-3-11 VDE 0126-1-1; VDE-AR-N 4105; EN 50438; Synergrid C10/C11 06/2012; Grid interfaces ÖNORM E8001-4-712 + A1: 04/2014 Quick installation guide for RPI M6A M8A M10A inverters...