Scanner area removals

Note: After replacing the ADF assembly, the flatbed unit, or CCD, you will need to run the scanner registration
procedure and scanner calibration procedure. These are located in the Diagnostics menu and Calibration menu.
For more information see

ADF assembly removal

1.
Remove the cord cover. See
2.
Remove the rear cover.
3.
Remove the two thumbscrews (A) that secure the ADF cable to the flatbed assembly.
4.
Remove the thumbscrews securing the ADF and flatbed hinges to the flatbed.
5.
Tilt the ADF assembly up and lift it away from the flatbed assembly.
Note: After installing the new ADF assembly, perform the scanner calibration procedures. See
"Adjustments" on page
"Adjustments" on page
4-205.
"Cord cover" on page
A
4-205.
4-6.
Repair information
7541-03x
4-113